Transform model cards¶
Every built-in transform has a packaged model card available through medaugmentx.model_card. These describe the implemented approximation and its input domain; no card establishes clinical validity.
RandomAffine¶
Input: real 2D/3D; any intensity units. Units: degrees; dimensionless scale; fraction/voxels/mm translation.
q = F(p-c)+c+t; physical F uses the grid metric
active anatomy warp on a fixed patient grid; mask order 0.
Limits: Spline interpolation can overshoot; angles are in the image frame, not anatomical RAS axes.
References: Source 1.
RandomFlip¶
Input: real 2D/3D; task permits reversal. Units: array axis; probabilities.
q[a] = size[a]-1-p[a]
active anatomy reflection; optional explicit label permutations.
Limits: Array x is not automatically anatomical left-right; presets disable flips by default.
AnatomicCrop¶
Input: real 2D/3D; optional integer mask. Units: positive voxel counts; foreground threshold in native units.
q = p - crop_origin
foreground means nonzero mask or image above threshold.
Limits: Biased sampling can change class prevalence; it does not identify anatomy.
ElasticDeform¶
Input: real 2D/3D; integer labels. Units: alpha/sigma/cap in voxels or mm along grid axes.
out[q] = in[q+d(q)]
Gaussian-smoothed fields; sampled gradient limiting; conservative global box bounds. Constant image padding uses nearest-boundary field extension for target inversion; conservative boxes do not require corner inversion.
Limits: Discrete Jacobian checks do not prove global anatomy; conservative boxes can be loose.
References: Source 1.
CoarseDropout¶
Input: real 2D/3D. Units: hole extent as axis fraction; fill in image units.
out[hole] = fill_value
occlusion preserves labels unless fill_mask=True.
Limits: Does not simulate a particular detector or pathology.
Resize¶
Input: real 2D/3D; registered targets. Units: target voxel counts.
p = (q+0.5)*old/new-0.5
full voxel extent preserved, including singleton axes; optional image antialias.
Limits: Resampling can remove small labels; spline overshoot is optional to clamp.
References: Source 1.
Pad¶
Input: real 2D/3D. Units: target voxel counts; fill in image units.
q = p + padding_before
sampling-grid affine is updated; mask padding is background 0.
Limits: Fill is not inferred from modality; choose CT air or normalized background explicitly.
CenterCrop¶
Input: real 2D/3D. Units: target voxel counts.
q = p - floor((old-crop)/2)
sampling-grid affine is updated.
Limits: Targets may leave the frame; pruning is explicit.
GaussianNoise¶
Input: real image in the declared native or normalized domain. Units: sigma in intensity units, or fraction of image standard deviation.
out = image + N(0,sigma^2)
independent Gaussian perturbations per voxel.
Limits: Approximation for CT noise; does not model dose, reconstruction kernel, or spatial correlations.
RicianNoise¶
Input: nonnegative magnitude signal in the declared intensity domain. Units: per-complex-channel sigma in intensity units.
out = hypot(image + N1, N2)
independent equal-variance real/imaginary Gaussian channels.
Limits: Already noisy magnitude input is an approximation; multi-coil/reconstruction statistics can differ.
GammaCorrection¶
Input: finite real image with a nonzero range. Units: positive dimensionless gamma.
out = lo + range*normalize(image)^gamma
per-image min-max normalization; optional inversion.
Limits: Changes calibrated intensity semantics; outliers affect the normalization.
BiasField¶
Input: finite real image. Units: dimensionless log amplitude; coarse voxel grid.
out = image * exp(clipped_interpolated_log_field)
smooth multiplicative appearance field.
Limits: Not a B0/B1 or coil sensitivity simulation; large alpha can be unsuitable.
WindowLevel¶
Input: native CT/HU or explicitly declared image units. Units: center/width in native units; perturbation fractions.
out = clip(image, center-width/2, center+width/2)
optional output normalization is explicit and updates domain metadata.
Limits: Display mapping, not acquisition dose/protocol simulation.
BrightnessContrast¶
Input: native or normalized input as configured. Units: brightness in intensity units; dimensionless contrast.
out = image*contrast + brightness
scalar contrast is a fixed multiplier.
Limits: Does not simulate calibrated exposure or detector physics.
GaussianBlur¶
Input: real 2D/3D. Units: sigma in voxels or per-axis mm.
out = GaussianFilter(image, sigma)
same sampled sigma; mask unchanged.
Limits: Separable grid-axis blur; mm on a sheared grid is not an isotropic RAS kernel.
MedianBlur¶
Input: real 2D/3D. Units: positive odd voxel window size.
out[q] = median(local_window)
mask unchanged; cube/square neighborhood.
Limits: Large 3D windows are expensive; not a physical acquisition model.
SimulateLowResolution¶
Input: real 2D/3D. Units: dimensionless downsample factor.
out = upsample(downsample(antialias(image)))
voxel-extent sampling; output grid and mask remain fixed.
Limits: Approximation to resolution loss, not scanner PSF or acquisition reconstruction.
CLAHEContrast¶
Input: finite real image. Units: relative histogram clip limit; tile counts; bins.
out = blended_local_clipped_histogram_CDF(image)
3D is processed slice-by-slice on array axis 0.
Limits: Implementation-specific CLAHE; may introduce inter-slice intensity differences.
HistogramMatch¶
Input: finite image; reference training distribution. Units: dimensionless blend; quantile count.
out = (1-blend)*image + blend*reference_CDF_inverse(source_CDF)
reference quantiles saved instead of reference image.
Limits: Fit references on training data only; histogram matching does not preserve HU calibration.
SlabShift¶
Input: 3D stack. Units: signed slices; fill in intensity units.
q = p + (shift,0,0)
active anatomy shift on fixed grid; mask and targets shifted.
Limits: Image-domain reconstruction-center approximation; targets may leave the frame.
LimitedAngleBlur¶
Input: 3D stack. Units: arc degrees; sigma in slices.
sigma = base_sigma*reference_arc/arc
Gaussian blur only on array slice axis.
Limits: Inverse-angle relationship is heuristic; no projection/reconstruction model.
SliceDropout¶
Input: 3D stack. Units: integer slice count; fill in intensity units.
out[selected_slices] = fill
mask remains unless affect_mask=True.
Limits: Robustness corruption; not a validated missing-frame acquisition simulator.
AnisotropicElastic¶
Input: 3D stack. Units: per-axis alpha/sigma in voxels or mm.
out[q] = in[q+d(q)]
delegates to bounded ElasticDeform in zyx order.
Limits: Defaults require dataset review; conservative box bounds can be loose.
CompressionVariation¶
Input: 3D stack. Units: dimensionless in-plane scale.
q[a] = center[a] + scale*(p[a]-center[a])
fixed output grid; labels use nearest neighbor.
Limits: Appearance approximation along one axis; not a mechanical breast-compression model.
ReconStreak¶
Input: 3D stack. Units: dimensionless amplitude/decay; voxel shifts.
out = image + sum(weight*shifted_neighbor_planes)
neighbor replicas with in-plane parallax.
Limits: Heuristic reconstruction appearance; not calibrated to scanner geometry.
GhostingArtifact¶
Input: real MRI-like magnitude image. Units: relative replica amplitude; shift in voxels.
out = image + sum(amplitude*rolled_image)
periodic shifted image-domain replicas.
Limits: No acquisition timing or complex phase model; not all MRI ghosting.
KSpaceDropout¶
Input: real reconstructed image; MRI approximation. Units: fraction of phase-encode lines.
out = abs(IFFT(mask * FFT(image)))
independent 2D FFT corruption per slice.
Limits: Measured complex k-space is unavailable; DC line removal can drastically change mean.
MRIMotion¶
Input: real MRI-like reconstructed image. Units: degrees; voxel translations; state count.
out = mean(original, moved_image_states)
same in-plane motion states for every slice.
Limits: Image averaging differs from motion during actual k-space acquisition.
BeamHardening¶
Input: native or normalized CT-like image. Units: alpha as image-range fraction; dimensionless power.
out = image - alpha*image_range*radial_bowl
fixed image-centered cupping profile.
Limits: No spectrum/material/ray tracing; can darken background or off-center anatomy.
MetalStreak¶
Input: native or normalized CT-like image. Units: range-relative amplitude; angular lobes; radial falloff fraction.
out = image + range*amplitude*starburst_field
random source locations shared across slices.
Limits: Not metal segmentation, sinogram corruption, or a reconstruction simulation.
ScatterSimulation¶
Input: real radiograph-like image. Units: relative fraction; sigma in voxels.
out = image + fraction*GaussianBlur(image)
smooth image-domain additive background.
Limits: No photon transport or detector response; sigma affects all axes on 3D input.
GridArtifact¶
Input: real radiograph-like image. Units: relative amplitude; cycles per pixel.
out = image*(1+amplitude*sin(2*pi*frequency*x+phase))
sinusoidal stationary stripes.
Limits: No grid geometry/motion model; parameters near Nyquist can alias.
NormalizeIntensity¶
Input: finite real image. Units: percentiles in [0,100].
out = (clip(image,lo,hi)-lo)/(hi-lo)
deterministic; constant images become zero.
Limits: Changes intensity calibration; use before normalized-domain effects, never to preserve HU.