Migrating to 1.0.0

Version 1 establishes the public NumPy/SciPy API and changes numerical behavior. Keep the original environment when reproducing pre-1.0 studies. Saved policies are configurations; they do not make old numerical behavior portable.

Patient coordinates and resize

MedVolume.affine is a finite nonsingular 4×4 matrix mapping array indices (z, y, x) or (y, x) to RAS millimetres. Its first ndim columns define the grid basis; its last column is the origin. spacing is the length of those basis vectors. With no affine, patient geometry is unknown, even if spacing is provided. Array x is a column direction, not automatically anatomical left/right. Legacy metadata['affine'] is interpreted as native XYZ-to-RAS and migrated; new code should use the field. Do not mutate spacing independently of affine.

Crop and pad translate the output grid. Resize preserves the full voxel extent: q = (p + 0.5) * new_size / old_size - 0.5 for targets and p = (q + 0.5) * old_size / new_size - 0.5 for image sampling. This convention also handles singleton axes and matches SciPy grid_mode=True. Downsampling anti-aliasing is enabled for images; masks always use nearest-neighbour sampling. Active affine/elastic/flip augmentation moves anatomy on the existing grid.

NIfTI loads reverse native spatial axes and convert metre/micron headers to mm. Loaded arrays own their data and release source-file memory mappings, including on Windows. Loading materializes the image and optional mask in memory. Image and mask_path must share a patient grid. Files with neither a coded qform nor a coded sform load with unknown geometry (affine=None) and their voxel sizes as spacing. Export writes one matrix to sform and qform under the code of the space it came from; shear is retained in sform with qform disabled. Unknown-grid export warns and writes codes 0; set allow_assumed_geometry=False to require known patient geometry.

Geometry and target behavior

RandomAffine(space='physical') now preserves physical distances for rotations without scaling, including anisotropic/sheared grids. Its angles are in an orthonormal image frame, not RAS anatomical axes. space='voxel' selects the legacy index metric. Translation units can be fraction, voxels, or mm along grid axes. DBT presets scale only in-plane by default.

Elastic fields now limit sampled displacement gradients by default. Optional min_jacobian rejects bad sampled determinants. These numerical checks do not establish anatomical realism or global continuous invertibility. Targets use iterative pull-field inversion and raise if it fails. Boxes use conservative global displacement bounds by default; these can be loose. Choose bbox_mode='corners' for the previous approximation or 'reject' to disallow boxes. Conservative boxes are computed directly without corner inversion. For constant image padding, inverse target mapping extends the displacement field with its nearest boundary value; image/background fill remains constant. units='mm' converts component/smoothing lengths along each grid axis; separable filtering on a sheared grid is not isotropic in RAS. Affine/elastic image and label resampling share the chosen boundary-extension mode, with constant label fill always zero; reflected image context carries reflected labels.

Presets and input domains

Presets disable flips unless allow_flip=True. Decide whether reversal is valid for your task, then explicitly remap laterality classes if needed: RandomFlip(label_map={1: 2, 2: 1}); landmark/box label maps are also supported. Mappings must be involutions. Array orientation alone cannot identify laterality.

MRI, DXR and DBT appearance parameters expect nonnegative, approximately [0,1] inputs. Use their normalize=True option for per-volume percentile clipping and normalization. This can discard absolute intensity information; use training-set preprocessing instead when that information matters. CT presets take HU, retain HU internally and use air fill -1000; normalize_output=True explicitly windows the final result to [0,1]. Presets are starting policies, not tuned defaults. Rician noise is a single-complex-signal magnitude perturbation; modality effects are documented approximations, not scanner simulators.

VolumeValidator.max_foreground_loss measures each nonzero class in physical area/volume by default. Choose foreground_measure='voxels' for count-based behavior. Guard statistics expose attempts, rejections, reverts and reasons. catch_errors=True treats ValueError/FloatingPointError draws as failures; programming errors propagate. Monitor fallback rates rather than silently assuming every training image received augmentation.

Policies, worker seeding and replay

JSON/YAML writers now emit schema/library versions and a canonical policy hash. Loaders still accept legacy documents with a warning; review and re-export them. Nonfinite values, invalid sizes/ranges and cyclic documents fail early. Histogram references serialize compact quantile summaries instead of image arrays.

A transform instance cannot occupy multiple pipeline positions or parents. Construct a fresh instance or deepcopy it. Container seeds still override child streams. reseed(seed) restarts a policy. apply_for_sample derives a stable seed from experiment seed, sample ID, epoch and augmentation index, independent of worker assignment. Explicitly pass the epoch to worker copies, including persistent workers; updating only the parent dataset does not update them.

record_augmentation stores exact RNG checkpoints, branch decisions, policy, environment and input/output fingerprints. replay_augmentation verifies the same environment and input before replay. Records contain no input image or metadata, but policies may describe data distributions. Review artifacts before sharing. Hashes detect changes and provide no authenticity guarantee. Custom transforms need registered constructors and serializable configuration; hidden state outside the RNG is not replayed. See examples/preview_and_replay.py.

Integration limits

PyTorch tensor processing is CPU NumPy/SciPy processing and is not differentiable. Adapters support single-channel images with an optional registered label image. MONAI/TorchIO use native XYZ spatial order by default; plain mapping adapters use array order unless configured. Current MetaTensor affine is propagated; pre-existing MONAI inversion history is cleared because these operations do not provide MONAI inverse transforms. Missing configured labels, additional TorchIO images, and mismatched grids raise rather than silently desynchronize samples.

DICOM strict loading supports classic monochrome single-frame CT/MR/CR/DX/MG objects with coherent geometry. It preserves regular shear/gantry tilt. Enhanced, multiframe, irregular stacks, functional groups, real-world/LUT mappings and unsupported SOP classes raise. Decode codecs must be installed for compressed pixel data. strict=False can skip unreadable/non-image candidates, with warnings and skipped_files diagnostics; it does not override incompatible known geometry. PatientID is omitted unless include_patient_id=True. Selected source paths and UIDs remain metadata; this loader does not de-identify a dataset.